Solution
Fixed air sampling with maximum safety
Reliable microbial monitoring in isolators and cleanrooms
The fixed air sampler for those who require reliable microbial monitoring in isolators and cleanrooms. With 100 lpm and validated high collection efficiency, it delivers fast and accurate results – every time. Robust construction combined with validated performance – a dependable choice for all critical cleanroom environments.
- Certified per ISO 14698 and EN 17141
- Independently tested for physical and biological efficiency
- 316 stainless steel, screwless design and weight under 2.5 kg
- Minimal turbulence thanks to parallel air exhaust
- Easy integration via Modbus, 24V/12V DC and robust Push-Pull connectors
- Remote control and selectable LED status ring for smooth operation
- Compatible with both contact plates and Petri dishes

Benefits and features
Contact plate or Petri dish
Choose between contact plates and Petri dishes depending on your requirements and sampling routines.
Screwless design
Easy cleaning and minimal contamination risk thanks to a fully screwless construction.
Parallel air exhaust
Air exhaust runs parallel to the sampling path, eliminating turbulence around the sampling point.
Compact and lightweight
Weighing under 2.5 kg with compact dimensions, it fits in all installation spaces, including tight isolators.
Easy system integration
Modbus RTU (Modbus TCP/IP and Profibus as options), 24V DC and robust stainless steel Push-Pull connectors for connection to BMS or isolator control panel.
Remote control and LED status
Included remote control for start/stop and optional 360° LED ring showing instrument status in real time.
Product images
Click on an image to enlarge.
Technical overview
| Flow rate | 100 L/min |
| Material | Electropolished 316L stainless steel |
| Dimensions (OD × H) | ⌀100 × 230 mm |
| Weight | 2.5 kg |
| Power supply | 100–240 V / 50–60 Hz |
| Communication | Modbus RTU (TCP/IP and Profibus optional) |
| Control | 24V DC, Push-Pull connectors, remote control |
| Standards | ISO 14698, EN 17141, CE |
Applications
- Continuous microbial monitoring in isolators
- Fixed-mount sampling in Grade A/B cleanrooms
- Aseptic production and sterile environments
- RABS systems
- Pharmaceutical production with GMP requirements
- Integration with BMS or isolator control systems
Documentation & compliance
Download supporting documents covering audit trail, regulatory compliance and data integrity.
Available models
Available in 3 variants to suit different requirements and workflows.
FS100-S-P – Petri Dish
| Type | Petri dish |
| Flow rate | 100 L/min |
| Material | Electropolished 316L stainless steel |
| Dimensions (OD × H) | ⌀100 × 230 mm |
| Weight | 2.5 kg |
| Power supply | 100–240 V / 50–60 Hz |
| Part number | FS100-S-P |
FS100-S-C – Contact Plate
| Type | Contact plate |
| Flow rate | 100 L/min |
| Material | Electropolished 316L stainless steel |
| Dimensions (OD × H) | ⌀100 × 230 mm |
| Weight | 2.5 kg |
| Power supply | 100–240 V / 50–60 Hz |
| Part number | FS100-S-C |
FS100-R-S-P – Petri Dish with 360° LED
| Type | Petri dish |
| Flow rate | 100 L/min |
| Extra | 360° LED status ring |
| Material | Electropolished 316L stainless steel |
| Dimensions (OD × H) | ⌀100 × 230 mm |
| Weight | 2.5 kg |
| Power supply | 100–240 V / 50–60 Hz |
| Part number | FS100-R-S-P |
Recommended instruments
These instruments are suitable for fixed installation.
Other installation types
Mobile Installation
High collection efficiency with full flexibility in the field
The portable air sampler combines high collection efficiency with full flexibility in the field. With 100 lpm and validated performance per ISO 14698 and EN 17141, you get fast, safe and reproducible sampling – regardless of environment. Mobility, precision and validated safety – perfect for critical environments where reliable sampling is a must.
Learn moreMulti-Point Installation
Control up to 8 air samplers from a central control panel
Multi-point installation air sampler, ideal for isolators, capable of flow rates of 100 or 180 lpm with validated high collection efficiency. The air sampler meets both ISO 14698 and the new standard EN 17141 for cleanrooms and associated environments. Manufactured in 316 stainless steel with a weight under 2.5 kg, with air exhaust parallel to the sampling path to reduce turbulence. 24V DC and Modbus RTU communication protocol for connection to BMS or isolator control panel with robust stainless steel Push-Pull connectors. Supplied with remote control for simplified operation and optional LED ring for status monitoring.
Learn moreContact
Interested in fixed installation?
Describe your environment and needs – we will get back to you with a proposal for the right instrument and configuration.
What happens next?
Quick response
We get back to you within 1 business day
3-5 questions
We ask questions to find the right approach
Proposal + quote
You receive a tailored proposal

Need help choosing the right solution?